PowerBay+ BDFB DC Distribution Bay

Commnets PowerBay+ BDFB is a modular breakerfuse bay with industry-leading monitoring, safety, and ease-of-use features. Available in 2, 4, 6, or 8 bus versions, the PowerBay+ BDFB is rated at up to 1200A per bus, up to 9600 amps total load. The bus configuration can be easily changed in the field by adding or removing bus straps, which can be safely done with the BDFB energized. Advanced monitoring features include bus voltage, total bus current, and optional individual load current. Bay status can be remotely monitored via HTTP, SNMP, and Modbus.

Features
View Complete Details

PowerBay High Density BDFB DC Distribution Bay

Overview
The PowerBay High Density BDFB DC Distribution Bay is a small footprint DC distribution cabinet for multiple applications. Measuring at 7 high, it has a small footprint requirement that installs in typical existing customer rack spaces. It includes removable, powder-coated steel side panels for wiring access, removable clear plastic rear panels, and front panel powder-coated steel blanking plates for unused panel positions.

Features
High power density and ampacity
Dual, Triple, or Quad bus configurations (1200A per input bus)
Front access bullet terminal circuit breakers
CSI HDDC high density bullet terminal breaker-panels accept 5100A single-pole or 150200A dual-pole circuit breakers
Cable management features lacing bars and guides that provide for neat, organized, and reliable inputoutput cable routing
Supervisory controllers provide voltage, current, and breaker trip alarms, per circuit current monitoring, and ethernet
GJX panels accept 100A225A single-pole, 250A400A dual-pole GJ1P circuit breakers
Downloads
View Complete Details

Sidecar PDF Small Footprint Primary Distribution

Overview
The Sidecar PDF is a small footprint side-mounted PDF system for adding additional primary distribution to Commnet power plants. Bus connections allow for easy connection to existing Commnet power plants without any additional cabling. Tiered internal terminations allow for easy landing and lacing of cables inside the cabinet. The system is available in left and right mount, with GJ Breaker and TPL fuses for over current protection. It is also available in an optional standalone configuration featuring a top feed solution.

Features
1800A, 2900A, and 4000A Maximum Distribution Ampacity Options available
TPL Fuse Positions or Large Frame Circuit Breaker Output Circuit Protection
Small 12 in x 25 in Footprint
Direct Bus Connection to Power Plant or Standalone Cable Options for Input
Mounts to side of Commnet PowerPlant Systems
Available in Left and Right Mount Configurations
Unmatched safety & reliability
View Complete Details

DCX - Top Teriminal Battery Disconnect System

Features
High ampacity DC battery disconnect device for telecom applications
Top terminal mount
400 1, 200 ampere models
Hydraulic-magnetic circuit breaker over-current protection versions
Non-current limiting, switch-only versions
Optional integrated NFPA code compliant thermal runaway detection system
Downloads
View Complete Details

DCX LP - Low Profile DC Battery Disconnect System For C&D Battery Stac

Overview
The DCX Low Profile is designed to work with C&D Battery stacks and provide battery disconnect functionality where rack to ceiling space is limited. The design provides cable access on the top, back, left or right sides of the disconnect enclosure to maximize installation flexibility when used in space constrained applications.

Features
High ampacity DC battery disconnect device for telecom applications
Low profile enclosure design
1, 000 and 1, 200 ampere models
Non-current limiting, switch-only versions
Integrated NFPA code compliant thermal runaway detection system
Integrated chargedischarge current measurement, local display and remote network accessible data
View Complete Details

DCX LP - Low Profile DC Battery Disconnect System For Unigy II Battery

The DCX LP DC Battery Disconnect System provides over-current protection for battery sourced equipment and wiring. It also functions as a service disconnect in order to maintain batteries, or to shut down the battery source connection in emergency situations. The DCX LP features a low profile enclosure design for locations with limited height allowance. It also provides multiple cable routing options to maximize installation flexibility in space constrained applications. Our Thermal Runaway Detection (TRD) system is included. All necessary installation hardware is shipped with the DCX LP and installation does not require additional drilling or hardware. Installation and operation are simple.

Features
High ampacity DC battery disconnect device for telecom applications
Low profile enclosure design
Breaker trip rating of 1200A
Top rack mounting configuration with multiple cable routing options
Hinged flip-up front access panel
Clear removable inspection window covers for lug mounting access
Downloads
View Complete Details

DCX RW - Rack- Or Wall-Mount Battery Disconnect System

Features
High ampacity DC battery disconnect device for telecom applications
400 - 1, 200 ampere models
Magnetic circuit breaker over-current protection versions
Optional current shunt
Non-current limiting, switch-only versions
Optional integrated NFPA code compliant thermal runaway detection system
Wall mount and rack mount configurations available
Reversible left-swing or right-swing door
Flexible cable entry
View Complete Details

AM Breaker Panel - For PowerBay+ BDFBs

Commnets AM Breaker Panel is an advanced vertically-oriented circuit breaker module that provides robust, high-density DC power distribution for rack mount servers and broadband applications. The AM Breaker Panel is available with an 800A or 1200A maximum rating and can be easily installed into Commnet Systems' PowerBay+ Full and Half-sized BDFBs.

Features
22 bullet circuit breaker positions
Per-breaker current measurement
800A and 1200A maximum rating available
Alarm LED per breaker
Breaker compartment light
Hot pluggable
Supports up to 125A per single pole circuit breaker
Modular design
Unmatched safety & reli
View Complete Details

GJ Breaker Panel

Features
(6) GJ breaker positions
1200A maximum rating
Alarm LED per breaker
Modular design
Unmatched safety & reliability
View Complete Details

H2Zero VRLA Battery Room Hydrogen Ventilation System

CSI introduces an innovative "drop-in" solution for providing NFPA fire code-compliant venting and hydrogen detection for Valve Regulated Lead Acid (VRLA) battery rooms in communications facilities. The H2 Zero system provides hydrogen sensing, temperature sensing, and -48VDC powered fan air movement for battery rooms. The CSI H2 Zero is an integrated, complete solution for high reliability battery room venting, hydrogen outgassing detection, and remote alarm.

Features
Integrated VRLA battery room ventilation system is fire code-compliant
Remote sensor modules for hydrogen and temperature measurement
Included adapter allows interfacing with standard 6-8" round HVAC ducting
Internal fan tray allows reversal for either intake or exhaust operational selection
1, 500 CFM N+1 redundant, and 2, 000 CFM non-redundant air flow
-48VDC input (dual redundant AB DC inputs with integrated input fuses)
Status and alarms displayed via wall-mounted supervisory control panel with LCD
Form C dry alarm contacts
Major and minor alarm contacts for remote alarm indication of hydrogen detection andor system fault
Integrated motor operated output damper (opens when fans operate)
Fire suppression interlock input (closes damper if fire suppression system active)
Downloads
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • (Comm/net Systems, Inc.)
  • Seattle, WA 98199 map, United States
  • Share us via

( ! ) Warning: Cannot modify header information - headers already sent by (output started at /htmlcachedir2/dynamic-html-pages/eitempfilen/usa/company/comm-net-systems-inc/other-products.htm:44) in /home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php on line 59
Call Stack
#TimeMemoryFunctionLocation
10.0005457896{main}( ).../index.php:0
20.02192028272include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/country-vanity/country_index_page_common_script.php' ).../index.php:309
30.03042750936include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php' ).../country_index_page_common_script.php:282
40.03723691296header ( ).../index.php:59
ExportersIndia: 404 Error Found
404Oops! It seems this page is not available

We connect Buyers and Sellers

Tell us What you Need

Trending Categories

Find Suppliers by Region


View All Categories

Find Suppliers by Country

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice