Our Products
Technical Specifications
Boiler output | kW | 35 (120kBtu) |
---|---|---|
Surface of exchanger | f2 | 30 |
Volume of fuel chamber | f3 | 367 |
Dimension of feeding opening | inches | 9.25 x 17.5 |
Prescribed chimney draught | Pa | 23 |
Max. operation overpressure of water | kPa | 250 |
Pressure loss of water (T 10K) | kPa | 4.4 |
Pressure loss of water (T 20K) | kPa | 1 |
Boiler weight | lb | 1014 |
Diameter of flue gas connection | inches | 5.9 |
Boiler height A | inches | 48.8 |
Boiler width B | inches | 27.6 |
Boiler depth C | inches | 52.75 |
Depth of chamber D | inches | 27.2 |
Protection of electrical parts | IP | 21 |
Electric output | W | 50 |
Boiler efficiency | % | 89 |
Boiler class | -- | 3 |
Flue gas temperature at nominal output | °F | 356 |
Substantive flue gas overflow at nominal output | kg/s | 0,021 |
Maximum noise level | dB | 65 |
Prescribed fuel | -- | Dry wood with heat value of 15-17 MJ/kg, water volume min. 12% -max. 20% diameter 80-150 mm |
Average fuel consumption | Kg/h | 9,1 |
Consumption per season | -- | 1 kW = 1 m3 |
Maximum length of wood logs | inches | 25.5 |
Burning time at nominal output | hod | 3 |
Volume of water in boiler | gallons | 29 |
Minimum volume of equalisation basin | l | 237.75 |
Connection voltage | V/Hz | 110/60 |
Technical Specifications
Rated Power Output | BTU | -- |
---|---|---|
European Standard EN 303-5 | -- | Yes |
Fuel Moisture Level | -- | Cord of Wood with a maximum of 30% moisture |
Power Range | BTU | 40-85K BTU |
Efficiency | % | 91.2 |
Possible Fuels | -- | Seasoned Wood, Briquettes, Corn Cobs with Kernels, 50% of Coal, Saw Dust, Wood Chips (50%), any kind of pellets |
Temperature Adjustment Range | A | 150-195 F |
Total Weight | Lb | 1190 |
Height with Controller Housing | A in | 59 |
Height of Hot Water Outlet | B in | 56 |
Height of Return Water Pipe | C in | 32 |
Height of Water Drain Valve | D in | 2.7 |
Height of Flue Pipe | E in | 46.5 |
Width with Clean-up Lever | F in | 25 |
Depth | H in | 39 |
Distance of Hot Water Outlet | I in | 9.5 |
Flue Pipe Size | J in | 6 |
Hot Water Outlet Pipe Size | G in | 2 |
Water Return Pipe Size | G in | 2 |
Drain Pipe Size | G | 3 |
Boiler Water Capacity | gal | 33 |
Flue Temperature | -- | -- |
-Max power output | A | 320 |
-Min power output | A | 195 |
Size of Loading Chamber | -- | -- |
depth | in | 19 |
height | in | 28 |
width | in | 18.5 |
Volume of Loading Chamber | gal | -- |
Noise Level | dB | 30 |
Power Consumption | W | 80W (1.4A) |
Voltage/Frequency | V/Hz | 120V/60Hz |
Technical Specifications
Boiler output | kW | 45 (154kBtu) |
---|---|---|
Surface of exchanger | f2 | 32.6 |
Volume of fuel chamber | f3 | 420 |
Dimension of feeding opening | inches | -- |
Prescribed chimney draught | Pa | 23 |
Max. operation overpressure of water | kPa | -- |
Pressure loss of water (T 10K) | kPa | 6.6 |
Pressure loss of water (T 20K) | kPa | 1.8 |
Boiler weight | lb | 1080 |
Diameter of flue gas connection | inches | -- |
Boiler height A | inches | -- |
Boiler width B | inches | -- |
Boiler depth C | inches | -- |
Depth of chamber D | inches | -- |
Protection of electrical parts | IP | -- |
Electric output | W | 60 |
Boiler efficiency | % | 90 |
Boiler class | -- | -- |
Flue gas temperature at nominal output | °F | 374 |
Substantive flue gas overflow at nominal output | kg/s | 0,027 |
Maximum noise level | dB | 65 |
Prescribed fuel | -- | Dry wood with heat value of 15-17 MJ/kg, water volume min. 12% -max. 20% diameter 80-150 mm |
Consumption per season | -- | -- |
Maximum length of wood logs | inches | 29.5 |
Burning time at nominal output | hod | 3 |
Volume of water in boiler | gallons | 33.8 |
Minimum volume of equalisation basin | l | 317 |
Connection voltage | V/Hz | -- |
Technical Specifications
Nominal output | 75 kW (256 KBTU) |
---|---|
Range of output setting (PROFI version) | 30-75 kW (102-256 KBTU) |
Prescribed chimney draught | 26 Pa |
Max water operation overpressure | 250 kPa (35 PSI) |
Pressure loss of water (T 10K) | 8.8 kPA (1.3 PSI ) |
Pressure loss of water (T 20K) | 1.6 kPa (0.23 PSI) |
Diameter of flue gas outlet | 200 mm (8) |
Loading chamber dimensions | -- |
Diameter of C.H. flow connection | 2 |
Diameter of C.H. return connection | 2 |
Protection level | 21 IP |
Maximum electric load | 4 A |
Boiler class | 3 |
Flue gas temperature by nominal output | 350 °F |
Flue gas flow by nominal output | 0.033 kg/s |
Average wood consumption | 18.7 kg/h |
Max wood log length | 1000 mm (40) |
Operation time by max.output | 2.5 h |
Volume of water in boiler | 164 l (43 Gal) |
Recommended accumulation tank min. volume | 500 Gal |
Range of water temperature setting | 65-90 oC ( 150 F to 195 F) |
Current carrying capacity of boiler regulato's contacts of (PROFI version) | 115V/4A |
Average wood consumption per season | 1kW=0.9m3 |
Efficiency | 86.2 % |
Fuel | Seasoned Wood (can be mixed with coal 40%) |
Electrical power connection | 115V/60Hz |
Weight | 650 kg (1422 lb) |
Heat-transfer surface | 3.6 m2 (39 sq/f) |
Max. noise level | 65 dB |
Feeding door size | 235445 mm ( 9.2x 17.5) |
Boiler width | 27.5 |
Boiler height | 57.5 |
Boiler depth | 66 |
Technical Specifications
Nominal output | 95 kW (325 KBTU) |
---|---|
Range of output setting (PROFI version) | 38-95 kW (140-325 KBTU) |
Prescribed chimney draught | 28 Pa |
Max water operation overpressure | |
Pressure loss of water (T 10K) | |
Pressure loss of water (T 20K) | |
Diameter of flue gas outlet | |
Loading chamber dimensions | L 41x W 21x H 31 |
Diameter of C.H. flow connection | |
Diameter of C.H. return connection | |
Protection level | |
Maximum electric load | |
Boiler class | |
Flue gas temperature by nominal output | |
Flue gas flow by nominal output | 0.035 kg/s |
Average wood consumption | 29.2 kg/h |
Max wood log length | |
Operation time by max.output | 3.5 h |
Volume of water in boiler | 250 l (65 Gal ) |
Recommended accumulation tank min. volume | |
Range of water temperature setting | |
Current carrying capacity of boiler regulato's contacts of (PROFI version) | |
Average wood consumption per season | |
Efficiency | 80.6 % |
Fuel | |
Electrical power connection | |
Weight | 800 kg (1900 lb) |
Heat-transfer surface | 5.6 m2 (60 sq/f) |
Max. noise level | |
Feeding door size | |
Boiler width | 30 |
Boiler height | 61 |
Boiler depth | 66 |