Post Buy Requirement
PI
United States
Add Review

Our Products #4954860

Vibration Absorbers - Stainless Steel

Packless vibration absorbers are designed for installation in the suction and discharge lines of air conditioning and refrigeration system to dampen the transmission of compressor-induced vibration through system piping.

Packless vibration absorbers are constructed of deep pitch corrugated tubing in stainless steel for increased flexibility and vibration absorption, covered with high tensile stainless steel wire braid for superior strength. The vibration absorbers have female copper end connections for making sweat connections to refrigerant piping.

Each absorber is pressure tested then carefully vacuum tested using a highly sensitive helium mass spectrometer leak detection device. Units are cleaned, dehydrated and sealed in plastic film after final inspection to maintain cleanliness and dryness prior to installation. These are available either in bulk or individually boxed.

Packless Vibration Absorbers are compatible with all HFC, HCFC and CFC refrigerants. The stainless steel models, VAFS-3 through VAFS-11, are electrically welded with no braze joints to achieve the higher working pressures set by todays industry standards.

Packless vibration absorbers are recognized under the component programs of Underwriters Laboratories, Inc., c-UL-US, File #SA2575.
View Complete Details

Ice Machine Coils

ackless ice machine coils utilize a coaxial tube-in-tube design. Water flows through the inner tube while refrigerant flows in the annulus between the inner and outer tubes.

The key to the high performance of Packless ice machine coils lies in the convoluted multi-lead inner tube manufactured in a patented process. The resulting convoluted tube has increased heat transfer surface area per unit length, yet still permits full flow of both water and refrigerant around its entire periphery for improved performance. Turbulence imparted by the convolutions to both the water and refrigerant flows further enhances the thermal performance, while inhibiting the accumulation of deposits on the surfaces. The net result is a highly effective, compact heat exchanger with superior anti-fouling characteristics.

Optimum heat transfer with Packless ice machine coils is achieved with a counterflow arrangement of water and refrigerant during condensing.
View Complete Details

Refrigerant Subcoolers

Mechanical subcooling involves cooling the liquid refrigerant of a low temperature system by evaporating the refrigerant of a high temperature system.

Since high temperature systems are more efficient than low temperature ones, mechanical subcooling provides a net gain in overall efficiency.

Packless chillers function well as subcoolers of either R-12. R-22 or R-502, and yield a low pressure drop for the subcooled liquid.

Seven chiller models are available to offer a wide range of subcooler capacities.
View Complete Details

Pull-Out Assemblies

lexible units are fabricated of red brass tubing having a continuous helical corrugation covered by bronze braid
Standard models have an SAE male flare connector at one end and an SAE female flare swivel of the same size on the other end
Eight different models of Packless pull-out assemblies are offered
Four different coupler sizes from 14 through 58 inches, each in lengths 36" and 48"
Consult factory for custom lengths
C-UL approved
Packless pull-out assemblies are designed to facilitate maintenance of compressors without disconnecting them from the air conditioning or refrigeration system.

Packless pull-out assemblies are constructed of deep pitch corrugated tubing for increased flexibility and covered by high tensile wire braid for superior strength.
View Complete Details

Evaporator Coils

Seven standard models are available ranging in capacity from 1 to 5 tons
Standard models are coaxial tube-in-tube design with a convoluted inner tube of copper and an outer tube (shell) of steel or copper
C-UL approved
ISO 9001:2008 certified
Working pressures:
CHAX-3100-H thru CHAX-3400-H:
Refrigerant side: 650 psig
Water side: 400 psig
CHAX-3500-J:
Refrigerant side: 620 psig
Water side: 400 psig
Packless chiller and evaporator coils utilize a coaxial tube-in-tube design. Water flows through the inner tube while refrigerant flows in the annulus between the inner and outer tubes.

The key to the high performance of Packless chiller and evaporator coils lies in the convoluted multi-lead inner tube manufactured in a patented process. The resulting convoluted tube has increased heat transfer surface area per unit length, yet still permits full flow of both water and refrigerant around its entire periphery for improved performance. Turbulence imparted by the convolutions to both the water and refrigerant flows further enhances the thermal performance, while inhibiting the accumulation of deposits on the surfaces. The net result is a highly effective, compact heat exchanger with superior anti-fouling characteristics.
View Complete Details

Double Wound Helix

7000 Series - High Efficiency Green Surface Coils
Excellent for both Water-Source Heat Pump and Water-Cooled Condenser applications
Highly effective convoluted inner tubes of copper or cupronickel
Fifteen standard sizes for 12 through 30 ton systems
Available in Helix, Spiral and Trombone Shapes
C-UL approved
ISO 9001:2008 certified
View Complete Details

Condenser Coils

Packless water-source condenser coils operate very effectively as either refrigerant condensers or refrigerant evaporators when transferring heat with water. This makes them an ideal choice for both water-source heat pumps and water-cooled condenser applications.

The coils utilize a coaxial "tube-in-tube" design. Water flows through the inner tube while refrigerant flows in the annulus between the inner and outer tubes.

The key to the high performance of Packless coils lies in the convoluted multi-lead inner tube manufactured in a patented* process. The resulting convoluted tube has increased heat transfer surface area per unit length yet still permits full flow of both water and refrigerant around its entire periphery for improved performance. Turbulence imparted by the convolutions to both the water and refrigerant flows further enhances the thermal performance, while inhibiting the accumulation of deposits on the surfaces. The net result is a highly effective, compact heat exchanger with superior anti-fouling characteristics.


The coils utilize a coaxial "tube-in-tube" design.
Optimum heat transfer with Packless water-source condenser coils is achieved with a counterflow arrangement of water and refrigerant during condensing.
View Complete Details

Vibration Absorbers - Brass

Eleven models available to fit copper tubing from 14 through 1 58 inches O.D.
Each unit pressure and vacuum tested, cleaned, dehydrated and sealed in plastic film
C-UL Approved
Notes:
Due to a continuous program of product improvement, specifications and dimensions are subject to change without notice.
For unusual installations, Packless vibration absorbers can be provided in special lengths or with PVC coating to protect them from condensation and freezing. Please consult factory with requirements.
View Complete Details

Refrigerant Heat Exchangers

Coaxial design for optimum heat transfer
Sizes to fit 13 to 50 H.P. capacity systems
13 H.P. through 10 H.P. constructed with copper outer tube and red brass inner tube
15 H.P. through 50 H.P. constructed with steel outer tube and stainless steel inner tube
C-UL approved
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • (Packless Industries)
  • Waco, TX 76702 map, United States