Post Buy Requirement
TP
United States
Add Review

Our Products #5144121

Bio Dewars

  • Weight 103 lbs
  • Overall Height 36″ 91 cm
  • Outside Diameter 22″ 56 cm
  • quantity 90 Liter
Overall Height 36
91 cm
Outside Diameter 22
56 cm
Necktube Diameter 6
15 cm
Empty Weight 77 lbs.
34.9 kg
Full Weight 274 lbs.
124 kg
Average static LN
2
Consumption Rate
(litersday) 0.4
Static Hold Time (days) 225
System Capacity (Ampules) 1800
Racks Included 8
Boxes per Rack 9
Box Capacity 25
Shipping weight 103 lbs in 3 boxes:
71 lbs., 26 lbs., and 6 lbs.
Shipping Box Size 3 boxes:
42 x 26 x 26
34 x 22 x 22
14 x 19 x 19
View Complete Details

Liquid Nitrogen Dewar

  • Weight 7 lbs
  • Dimensions 11 x 11 x 20 in
  • quantity 2 Liter
2 Liter Dewar Specs
Overall Height 15 12
394 mm
Outside Diameter 6.2
158 mm
Necktube Diameter 1 14
32 mm
Empty Weight 3.5 lbs.
1.6 kg
Full Weight 7.2 lbs.
3.3 kg
Evaporation rate
(litersday) 0.29
Static Hold Time
(days) 7
Shipping Weight 7 lbs
Shipping Box Size 11 x 11 x 20
View Complete Details

TechniSwitch

  • Series TS Series
Technifabs TS Series tank switchers provide continuous liquid nitrogen supply by automatically switching from the empty dewar to a full dewar. The TechniSwitch Tank Switchers are available in either a non-vacuum jacketed or vacuum jacketed version. The VJ unit offers low heat leak, minimal boil-off, no condensation, touchable casing and eliminates solenoid chatter. It is the most efficient and safe switcher in the industry.

Benefits

Reduces operating expenses by minimizing employees involvement in tank changeover.
Saves money by reducing system downtime during dewar replacements.
Empty tank alert and dry contact for customer provided alarm.
Additional benefits of the VJ version:

Improves environmental safety by eliminating pipe dripping and reducing slip hazards.
Reduces workplace hazard because outer casing is touchable.
Uses less liquid nitrogen through quicker cool-down enabling faster deliver to end use points.
Features

Allows a variety of different tanks and VGLs.
Easy operation using touch screen PLC controls with simple adjustment.
View Complete Details

Vacuum Jacketed Piping

  • Series Techniguard R-Series
  • Nominal Pipe Size 1/2″1 x 1 1/2″1
  • Outside Diameter in Inches (mm) 1.50 (38)
  • Dry Weight lb/ft (kg/m) 1.2 (1.7)
The high thermal performance of Techniguard R-Series rigid vacuum insulated pipe often saves our customers enough liquid nitrogen to pay for itself in less than a year. Our rigid pipe is maintenance free and warranted for ten years!
Delivers significant lifetime savings due to minimal cryogen loss.
Easily accommodates future expansions or modifications.
Provides longer, care-free service life, backed by our best-in-the-business warranty.
Provides a rapid return on your investment.
Easy Installation manufactured in easy-to-assemble sections with high-efficiency, low heat leak bayonet connections. No welding or refitting in the field required, its even easier to install than foam covered pipe!
Doesnt need expensive vacuum pumps that require maintenance like dynamic vacuum-jacketed systems.
ASME certification and CRN (Canadian Registration Number) are available.
View Complete Details

Liquid Helium Transfer Equipment

From bulk transfer hoses to stingers, Technifabs complete line of low heat-leak liquid helium transfer equipment
provides safe and efficient transfer of liquid helium.

We design and manufacture:

Helium transfer hoses unsurpassed in efficiency, meaning less helium loss to your equipment.
Cryostat and Dewar stingers available in a variety of standard configurations or custom made to your application.
Vacuum Jacketed LHe valves can be incorporated into our products or sold as stand alone items.
Manifolds built in any practical configuration. Common examples are liquid helium transfill stations where LHe is transferred from tanker truck to dewars for distribution.
Dewar fill hoses
Diptube extensions
View Complete Details

Cryogenic Vacuum Jacketed Valves

  • Series Techflow Pipe Series
Technifab offers a line of vacuum jacketed valves that gives you top cryogenic valve performance and also work best with vacuum jacketed pipe. These low heat leak vacuum insulated valves dont add unwanted heat to your cryogenic liquid, saving you money and loss of cryogens.

Benefits
Vacuum-jacketed, eliminating icing and condensation seen with non-vacuum jacketed cryogenic valves.
Self-aligning, PCTFE seat designed for flexibility and solid closure at cryogenic temperatures.
Wear parts are easily replaceable reducing down-time.
Redundant cryogenic bonnet seal provides an extra level of safety.
View Complete Details

Detector Dewars

Technifabs WhisperTech line of exceptionally quiet detector dewars can cover the entire electromagnetic spectrum. Detector dewars are used to reduce the temperature of an electromagnetic sensor and the first stage amplifier, often a field effect transistor. By reducing the temperature the noise level of the components are exponentially reduced. Thus a cleaner, better signal comes out of the detector used in the product.

WhisperTech line of detector dewars are constructed to the highest quality standards. Whatever tolerances you specify, our quality assurance program will ensure conformance on each and every unit. We understand the importance of reducing microphonics and will work with you on design and processes to deliver to you noise-free dewars.

Over the years we have developed a reputation for high quality and competitive prices. Whether the detector is for X-rays or Infrared radiation, undesirable thermal and vibratory mechanical noise is held to a minimum by using the Technifab manufactured dewar.
View Complete Details

Internal Cryogenic Gas Traps

Internal Gas Traps are typically installed in vertical drops to liquid nitrogen use points with non-vacuum jacketed terminations. The gas trap works by trapping a pocket of gas inside the line when liquid nitrogen is shut-off. This gas pocket prevents liquid nitrogen from reaching the non-vacuum
Benefits of using a gas trap include:

Reduced Heat Leak When liquid nitrogen is not flowing, the heat leak of a non-vacuum jacketed termination is about 200 BTUhour
(60 Watts). With an internal gas trap the heat leak is only about
0.5 BTUhour (0.15 Watts).
Eliminates Ice. When liquid nitrogen is not flowing your
non-vacuum jacketed terminations maintain a constantly dripping
ice ball. With an internal gas trap, this ice ball disappears.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • (Technifab Products, Inc.)
  • Brazil, IN 47834 map, United States
  • Share us via