Post Buy Requirement
UL
United States
Add Review

Our Products #5146735

OEM LAMP TAMARACK

  • Model Number LTIH-5004W
Part Number LTIH-5004W
Power (W) 5000
Voltage (V) 54 - 66
Current (A) 85
MinMax (A) 7692
Ignition Voltage (kV) 36
Min. Opern Circuit Voltage (V) 85110
Cooling (ftsec) 20
Diameter d (mm) 86.5
Length c max. (mm) 349
Length b max. (mm) 307
Distance a (mm) 143
Ferrule length f (mm) 70
Arc gap (cold) g (mm) 8.24
Lamp Life (hours) 750
Distribution wavelength (nm) 365, 405, 436
Operating position Vertical 10
Anode base 38 - 9.4
Cathode base 38 - 7.9
View Complete Details

Mercury Capillary Lamps

1. Capillaries are a Graded Seal Lamp, making this product impossible to hear in an annealing process. The quartz at the graded ends of the lamp has a lower melting point than the quartz body. The annealing process heats the lamps in a furnace for a given period of time. This process relieves the stress during the lamps manufacturing process. The lack of annealing results in a lamp that is very fragile requiring great care in installation.

2. The ON and OFF cycling of the lamp is temperature related. Capillary lamps are designed for intermittent operation only. The longer or hotter the burn period the shorter the lamp life. Typical life rating is 7000 shots at 40 seconds or less, 3000 shots for over 40 seconds. If the ON cycle is extended, the lamps internal pressure increases, as well as the potential for violent lap failure. It the OFF time is too short, the rise time into the mercury vaporization may be effected and the migration of the mercury away from the electrode to the center of the lamp will be inevitable. This will result in lamp instability and dark electrodes, resulting in early failure and possible lamp explosion.

3. It is critical for proper ignition to manually distribute the mercury into even pools at each end of the lamps in front of the electrodes (see instructions included with each lamp). If the mercury is not properly distributed, the operation ONOFF time may be affected, resulting in a hard-starting lamp which could fail or explode causing short life. As this lamp had a graded seal, there is a large dead spaced behind the electrode tip. This space must be filled to allow a certain portion of mercury to enter into ionization. If all the mercury does ionize, the lamp becomes saturated. Mercury Saturation resulting from an unbalanced lamp will cause unstable current regulation. IT IS VERY IMPORTANT TO BALANCE THE MERCURY!

4. Capillary lamps rated over 1KW require water-cooling. The user must evaluate the rated GPH for the required wattage. Water must be deionized and checked and changed frequently to eliminate ion concentration. Mechanical equipment must be checked frequently for water leaks and gasket failure.

5. Many lamps are returned for breakage during installation. As the lamps end is nickel-plated and the spring load in the system is the same, the lamp must be carefully installed to eliminate the lamps from slopping to one side from the two polished surfaces. This will result in a lamp slightly cocked to one side in the water jacket. This creates a thermal stress when the lamp is heated resulting in hairline cracks in the lamp body and early failure.
View Complete Details

Nightsun Searchlight

  • Series UL-XS1600/G
  • Power (W) 1, 600
  • Voltage (V) 25.3
  • Rated Current (A.D.C.) 58 - 65A
The ULS ULXS1600G244 is a DC-Controlled lamp that is specifically designed for applications requiring excellent ARC stability and high light output.
Current Control Range (A.D.C.) 58 - 65
Average Lumen Output (LM) 56, 000
Luminous Intensity (LM) 5, 800
Burning Position H2820 - V20
Forced Air Cooling (msec.) 10 - 13
Base - Pin or Thread (mm) Anode (+) 28-5 X 3 pins
Cathode (-) 28 - 9.5
View Complete Details

Starburst Searchlight

  • Series UL-XS500/R
  • Power (W) 500
  • Voltage (V) 20
  • Rated Current (A.D.C.) 25A
The ULS ULXS500R244 is a DC-Controlled lamp that is specifically designed for applications requiring excellent ARC stability and high light output.

Current Control Range (A.D.C.) 20 - 28
Average Lumen Output (LM) 16, 500
Luminous Intensity (LM) 1, 700
Burning Position H2820 - V20
Forced Air Cooling (msec.) 4 - 6
Base - Pin or Thread (mm) Anode (+) 19 - 4
Cathode (-) 25 - 9.5
View Complete Details

Halogen Lamps

  • Series EHG
There are many Quartz Halogen styles used for various applications, we have many of them in stock. These lamps are commonly used for studio, theater, TV & video
Any tungsten filament lamp can be used as an infrared heat source. The most practical are quartz halogen lamps. Tubular and reflector lamps have been most successful. Tubular quartz lamps are available in a number of wattages and voltages which allows for ramping using variacs or simple dimming devices.

Available in dichroic (thin film) reflectors or highly efficient gold coating, allows for various beam distributions, wattages, and voltages. Special high temp sockets and transformers available from inventory for optical package. (Ellipsoidal-designed reflector develops up to 1500C 19mm in front of lamp face.)
View Complete Details

Deuterium Lamps

Deuterium lamps create an arc between the anode and tungston filament that excites molecular deuterium. Light is emmitted as it transitions back to it's initial state. The intense continuum from the vacuum ultraviolet to 500 nm, and the low visible and infrared output, ensure superior signal to noise for many UV measurements.

We stock a number of different models from Heraeus, Hamamatsu and others, including part numbers: L1789, DO801, DO302, DO902, D1050, R.23, G.03, 3UNXGa, 5QNCu-Zn, Cu, Pb, As and Hollow Cathode.
View Complete Details

OPTI-BEAM LAMP

  • Model No. LTIH-5000W
Power (W) 5000
Voltage (V) 47 - 53
Current (A) 100
MinMax (A) 95105
Ignition Voltage (kV) 36
Min. Opern Circuit Voltage (V) 85110
Cooling (ftsec) 20
Diameter d (mm) 86.5
Length c max. (mm) 349
Length b max. (mm) 307
Distance a (mm) 143
Lead length e (mm) 260
Ferrule length f (mm) 70
Arc gap (cold) g (mm) 7.52
Lamp Life (hours) 750
Distribution wavelength (nm) 365, 405, 436
Operating position Vertical 10
Anode base 38 - 9.4
Cathode base 38 - 7.9
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • (Universal Light Source, Inc.)
  • San Francisco, CA 94103 map, United States
  • Share us via