Wireless Dynamics Sensor System

Use the WDSS with your Bluetooth-enabled computer and Logger Pro software, or with your LabQuest 2, to collect data free of friction due to cables. Internal data storage capacity allows you to use it as a stand-alone data logger, making it great for roller coaster physics. In addition, you can use the WDSS to do traditional experiments that you do with conventional accelerometers and force sensors. Using Multiple WDSSThe WDSS can be used alone, with one or more additional WDSS units, or with other Vernier interfaces. The WDSS does not require an interface unless the experiment requires the use of other sensors that are not included in the unit itself. Here are some common combinations: Two WDSS units connected by Bluetooth to a single computer for Newtons Third Law experiments.A WDSS used with a Vernier interface, Motion Detector, and a Dual-Range Force Sensor for impulse-momentum experiments.A WDSS with a Vernier interface and a Dual-Range Force Sensor for Newtons Third Law experiments.A WDSS, a Go!Motion, and a Vernier Dynamics System create an elegant impulse-momentum experiment setup.
View Complete Details

Anemometer

The Vernier Anemometer is an impeller-type anemometer that measures wind speed in the range of 0.5 to 30 ms (1 to 67 mph). The Anemometer fits in your palm for wind study measurements in the field. A standard camera mount on the back and an accessory rod allows you to position it in wind tunnels or in front of fans for wind turbine experiments.
View Complete Details

Barometer

Sensing Element: SenSym SDX15A4Pressure Range (as shipped): 0.8 to 1.05 atm (25 to 31.5 in of Hg)Maximum pressure that the sensor can tolerate without permanent damage: 2.04 atm or 61 in of HgSensitivity: 436 mVin of Hg to 13.06 Vatm.Typical Resolution: 1.0026 X 10-4 atm (0.003 in of Hg)Combined Linearity and Hysteresis: Typical 0.1% full scale, maximum 0.5% full scaleResponse Time: 100 microseconds
View Complete Details

Blood Pressure Sensor

Pressure range: 0 mm Hg to 258 mm HgMaximum pressure without permanent damage: 1550 mm HgTypical accuracy: 1 mm HgTemperature compensated: -20C to 85CSensing element: SSCMRRN005PGAA5Combined linearity and hysteresis: typical 0.25%Response time: 1 millisecond
View Complete Details

Charge Sensor

Unlike a traditional electroscope, the Charge Sensor can make quantitative measurements. Numerical measurements improve many electrostatics experiments, such as charging by induction, charging by friction, and charging by contact. The sensor can also be used to measure charge polarity. An extremely high-impedance voltage sensor with a 0.01F input capacitor makes these measurements possible. The sensor has three operating ranges and a zeroing switch to discharge the input capacitor.
View Complete Details

Colorimeter

Use this sensor to explore absorbance and percent transmittance in a variety of experiments including Beers law (absorbance vs. concentration) and kinetic studies (concentration vs. time). Students select between four wavelengths (430 nm, 470 nm, 565 nm, 635 nm) to set up their experiment. Go Direct Colorimeter features one-step calibration for all four wavelengths. Its as simple as inserting a cuvette of distilled water and pressing the Calibrate button. Go Direct Colorimeter can be used in a variety of experiments: Conduct Beers law investigations.Determine the concentration of unknown solutions.Study changes in concentration vs. time.Monitor reaction rates.
View Complete Details