We offer the best product range of Characteristics Power Rating: One UPS: 50 kVA to 500 kVA, in 25 kVA in, Galaxy VX, Galaxy VM, Symmetra Megawatt and Characteristics Power Rating.
Characteristics Power Rating: One UPS: 50 kVA to 500 kVA, in 25 kVA in
Characteristics Power Rating: 300400500 kVA Output Power Factor: 0.9 Parallell Capacity: Yes Input: 480V or 600V , 3 Phase Output: 480V or 600V Batter: Lead acid batteries (vented, sealed), NiCad
Application Mission-critical Environments Medium to Large Data Centers Industrial Plants
haracteristics Power Rating: 500625750 kVA (480 V); 100012501500 kVA N+1 (480 V) Input Power Factor: 99% @ >40% Load Output Power Rating: 1.0 kVA = kW Parallell Capacity: 00 750 kVA: Up to 4 + 1 (4 units for capacity + 1 for redundancy); 12501500 kVA: Up to 3 UPS units in N+1 configuration, where N is 2, 1 for redundancy; Up to 2 UPS units for capacity Input: 4880 V +20%-15% @ 100% load, 3 wire + G Output: 480 V, 3-wire (3PH + G) Batter: VRLA, Flooded, Li-ion
Application Mission-critical Environments Large to Extra Large Data Centers Facility Infrastructure Colocation Facilities Finance, Semicondustor and Manufacturing Envirnments
Characteristics Power Rating: 160180225 kVa Output Power Factor: 0.9 Parallell Capacity: Up to 4 units for capacity, 5 for redundancy Input: 480V (208 V with Transformer Output: 480V (208 Vwith Transformer Batter: VRLA, Li-ion
Application Mission-critical Environments Small to Medium Data Centers Facility Infrastructure Industrial Plants
Characteristics Power Rating: 10 to 100KW in 10Kw increments Output Power Factor: 1 Input: 208V 3 phase +N + G Output: 208 3 phase + N + G or 3P + G Batter: VRLA
Application Data Closets High Denisty Zones Small and Medium Data Centers
Characteristics Power Rating: 45/50/65/75 kVa Output Power Factor: 0.8
Characteristics Power Rating: 40506080100 kVa Output Power Factor: 0.9 Parallell Capacity: Up to 6 units for capacity or redundancy Input: 480V (208V and 600V with Transformer Output: 480V (208V and 600V with Transformer Batter: Integrated, adjacent, remote, open rack, VRLAl
Application Mission-critical Environments Medium Data Centers Telecom Centers Industrial Plants
Characteristics Power Rating: 10152030 kVa Output Power Factor: 0.8 Input: 208 -220 V 3(3ph +N +G) Output 200 -220 V 3(3ph +N +G) Batter: Integrated, maintenance-free, sealed lead acid
Application Small Data Centers Medical Server Rooms Laboratories Point Of Sale Government and Institutional
Characteristics Power Rating: 10152030 kVa Output Power Factor: 0.8 Input: 208 - 220 V 3(3ph +N +G) Output: 208V Batter: Integrated, maintenance-free, sealed lead acid
Application Telecom Ceneters Commercial Building Transporation and Infrastructures Technical Facilities Industrial Plants and Process Protection