Universal Isolation Transformers 6J

  • Input Primary Input/output Voltages: Reversible, allowing use of transformer in step-up or stepdown application.
  • 3 Phase Suffix A WYE 120/208V: WYE 120/208V Suffix B WYE 120/208V:DELTA220/240V Suffix C WYE 120/208V:DELTA 440V Suffix D DELTA 220/240V:DELTA 220/240V Suffix E DELTA 220/240V:DELTA 440V Suffix F DELTA 440V:DELTA 440V
  • Input Frequency 47-65 Hz
  • Regulation 10% or less no load to full load.
  • Operating Ambient Temperature 60 Degrees C Max.
3 phase and single phase modelsAll units feature electrostatic shieldingMultiple taps for a wide range of inputoutput combinations250VA-15KVA, 3 phase 250VA-10KVA, single phase
View Complete Details

Power Transformers E

  • Input primary 115 V AC, 400Hz ±20Hz, 1 phase.
  • Regulation Size A: 12% or less no load to full load.
  • Dielectric Withstanding Voltage 2500 V AC.
  • Efficiency Ranges from 86% to 96% typical.
  • Operating Ambient Temperature 85°C maximum.
Military Designation TF5S03ZZ.Encapsulated, rugged MIL-PRF-27 transformers.Capable of operation at high temperatures.For airborne, missile and space applications.
View Complete Details

Toroid Transformers TM/TF

  • Input Primary 115 V ac, 400 Hz ± 20 Hz, 1 phase. “A” Option: 230 V ac, Add suffix “A” to model number, e.g., TF10-1A.
  • Regulation 5% or less, no load to full load.
  • Secondary Voltage Tolerance Within 5% when measured at full load and listed input.
  • Efficiency 90% to 95% typical.
  • Construction Model TM – to meet MIL-PRF-27, Grade 5 Class S. Model TF- Open frame, Industrial Grade with Teflon leads 6″ long.
Designed for 400 Hz operationMore VA per size and weight than conventional power transformersGrade 5 Class S constructionIndustrial style Grade 6 also standard
View Complete Details

Power Transformers 4D

  • Input Primary WYE: 115V L-Com (Standard) WYE: 200 V L-L (Standard) DELTA: 115 V L-L Suffix A* DELTA: 200 V L-L Suffix B*
  • Input Frequency 400 Hz ± 20 Hz, 3 phase.
  • Dielectric Withstanding Voltage 1500 V rms.
  • Efficiency Ranges from 90% to 95% typical.
  • Construction To MIL-PRF-27 Grade 5, Class S.
MIL Grade 5 Class S constructionDesigned to meet the light weight and high temperature requirements of airborne, shipboard, and military electronicsDELTA or WYE selectable outputs400 Hz transformer with 4 different standard inputs60 VA to 50000 VA
View Complete Details

Power Transformers P

  • Input Primary 115 V ac, 60 Hz +5 Hz**, 1 phase. “A” Option: 230 V ac. Add suffix “A” to model number, e.g., 5P10CTA (Fig. 1). “B” Option: 115/230 V ac. Add suffix “B” to model number, e.g., 5P10CTB (Fig. 2).
  • Regulation 12% or less no load to full load (Sizes A1-A2) 10% or less no load to full load (Sizes A3-A11).
  • secondary Voltage Tolerance Within 3% of listed output voltage when measured at full load and listed input.
  • Efficiency Ranges from 80% to 90% typical.
  • Operating Ambient Temperature 95° C maximum.
Grade 4 Class S ConstructionHermetically sealed, rugged MIL-PRF-27 transformersStandard output voltages: 5 to 486 voltsThreaded inserts for versatile mountingWide range of power ratings: 5, 10, 15, 20, 30, 40, 80, 120, 160, 200, and 300 VA
View Complete Details

Power Transformers 6B

  • Input Primary 115 V ac. 50-65 Hz; 1 Phase (capable of 400 Hz operation). “A” Option: 230 V ac. Add suffix “A” to model number , e.g., 6B5-10A.
  • Regulation 15% maximum from no load to full load (6% on units s ize 8 and larger).
  • Secondary Voltage Tolerance Within 5% of listed output voltage when measured at full load and listed input.
  • Efficiency Ranges from 80% to 90% typical.
  • Operating Ambient Temperature 80° C maximum (70° C on units size 8 and larger).
High efficiency, excellent regulation and high isolationWidely used in custom power supplies and industrial power controls10 VA to 1300 V A
View Complete Details

Toroid Transformers R

  • Input Primary 115VAC, 400 Hz ± 20 Hz, 1 phase
  • Regulation Ranges from 10% to 23% maximum.
  • Secondary Voltage Tolerance Within 3% of listed output voltage when measured at full load and 115VRMS input.
  • Efficiency Ranges from 70% to 83% minimum.
  • Construction To MIL-PRF-27 Grade 5, Class S
Military Grade 5, Class SStandard output voltages 5 to 300 voltsCompact toroidal construction in a convenient printed-circuit mount package.Low outgassing molded construction for high-altitude operationPower levels 1. 5, 3, 6, and 9 VA
View Complete Details

Power Transformers 6DF

  • Input Primary WYE: 120VL-Com. or 208 V L-L Suffix A DELTA: 120 V L-L Suffix C DELTA: 230 V L-L Suffix E DELTA: 440 V L-L Suffix F
  • Input Frequency 50 Hz to 65 Hz, 3 phase.
  • Regulation 10% or less no load to full load; (6% on sizes 3 through 6).
  • Secondary Voltage Tolerance Within 5% when measured at full load and listed input.
  • Efficiency Ranges from 90% to 95% typical.
Industrial style standardCompact sizesOutputs-DELTA or WYE selectable5 different standard inputs availableIdeal for naval electronics, ground support equipment, industrial controls and telecommunications
View Complete Details

Front End

  • Voltages 190-450VDC Available
  • VRMS Input 80% Load >95% Efficiency
  • Short Circuit Protection EM! Compliant with MIL-STD-461
Compact, Low-Profile Design500-1500 watt Active Power Factor Correction Front Ends115 V or Universal Input with 190 to 450 VDC outputMIL-STD-461 and MIL-STD-1399 Section 300 compliant
View Complete Details

Power Transformers 6DM

  • Input Primary WYE: 120VL-Com. or 208 V L-L Suffix A DELTA: 120 V L-L Suffix C DELTA: 230 V L-L Suffix E DELTA: 440 V L-L Suffix F
  • Regulation 50 Hz to 65 Hz, 3 phase.
  • Secondary Voltage Tolerance Within 5% when measured at full load and listed input.
  • Efficiency Ranges from 90% to 95% typical.
  • Construction To MIL-PRF-27, Grade 5, Class S. Specify the Letter “M” in the model number, e.g., 6DM15-200. NOTE: MIL-PRF 27, add .20 to Dim. A, B, C.
MIL-PRF-27 Grade 5 Class S constructionIndustrial style also availableCompact sizesOutputs-DELTA or WYE selectable5 different inputs availableIdeal for naval electronics, ground support equipment, industrial controls and telecommunications