HACAB

Custom Controls Company custom manufactures vertical Wall Mount Air Conditioners suitable for operation up to 55oC131oF. Oversized variable frequency drives and motors rated for 70oC inverter duty guarantee the ability for these AC units to operate in the hottest regions on Earth. Units are fabricated in 3, 6, and 12-ton capacity to provide electric heating, cooling, ventilation, and pressurization for Industrial Explosion Proof and Hazardous Duty applications. All coils are protected with BLYGOLD PoluAl topcoat and 3509 primer. Units can be controlled individually or by LeadLag Controls for multiple redundancies. Typical applications include the Middle East and desert regions throughout the Earth. Class I, Groups BCD units comply with NEC 500 & 505 and NFPA Standards. Class I, Groups IIAB, Zone 1 & 2 units conform to IEC European Standards.
View Complete Details

LCAB

These units are custom-manufactured large vertical Wall Mount Air Conditioners. They range in size from 7.5 to 25-tons to provide electric heating, cooling, ventilation, and pressurization for Industrial Hazardous and Non-Hazardous Duty applications. These oversized Wall Mounts are constructed with 16-gauge galvanized steel. This style of AC is usually installed on pre-fabricated buildings prior to delivery, avoiding on-site Electrical, HVAC, and duct installation costs. Unlike roof or pad mounted air conditioners, they can usually be shipped attached to the building. Cabinets are coated with our industrial epoxy and polyurethane coating system. All coils and copper are protected with BLYGOLD PoluAl XT coil coating. Units can be controlled individually or supervised by LeadLag Controls for multiple units. Our Quality Control department conducts rigorous run-testing prior to acceptance for delivery. Typical applications include RIE Buildings, Motor Control Centers, Switchgear Buildings, Blast Buildings, Control Rooms, Offshore Drilling Rigs, and Locker Rooms. Class I, Groups BCD, Division 2 units comply with NEC 500 & 505 and NFPA Standards.
View Complete Details

Cab

Energy efficient vertical Wall Mount, Heat Pump, and Step-Capacity Air Conditioners provide electric heating, cooling, ventilation, and pressurization for Industrial Explosion Proof and Hazardous Duty applications. Typical applications that require include Analyzer Shelters, RIE Buildings, Motor Control Centers, Blast Buildings, Switchgear Buildings, Offshore Drilling Rigs, Containers, Man Camps, Storage Facilities, etc. Units range from 1.0 to 6.0 tons. Division Two condenser section wiring is protected by liquidtight conduit. All coils are protected with BLYGOLD PoluAl XT coil coating system. Units are furnished complete with thermostats and wall grilles. Hazardous Location heater assemblies utilize low watt density stainless steel heating elements. Hazardous duty units annunciate faults with time stamp for easy troubleshooting. Units can be controlled individually or by LeadLag Controls for redundant units. No onsite refrigerant piping or exterior ductwork is required for Wall Mount installation. Class I, Groups BCD, Division 1 & 2 conversions comply with NEC 500 & 505 and NFPA Standards. (Group B, Division One Explosion Proof units require customer-furnished source of purge air). Class I, Groups IIAB, Zone 1 & 2 modifications conform to IEC European Standard.
View Complete Details

Pad Mount Package Air Conditioners

Roof and Pad Mount Package Air Conditioners range from 2 to 30 tons to provide electric heating, cooling, ventilation, and pressurization for Industrial Explosion Proof and Hazardous Duty applications. All coils are protected with BLYGOLD PoluAl topcoat and 3509 primer. Units require connecting supply and return ductwork, thru-the-roof duct sleeves, support frame or concrete pad, etc. Typical applications include RIE Buildings, Motor Control Centers, Blast Buildings, Offshore Drilling Rigs, Containers, Man Camps, Storage Facilities, etc. Class I, Groups BCD, Division 1 & 2 units comply with NEC 500 & 505 and NFPA Standards. Class I, Groups IIAB, Zone 1 & 2 modifications conform to IEC European Standards. OPTIONS: 50 HertzXP Electric Heat304 or 316 Grade Stainless Steel CabinetIndustrial Cabinet CoatingPressurizerAuxiliary BlowerFiltered Fresh Air Intake BoxIntake Stack (mounted or self-supported)Interface Contacts for Customer EquipmentSpark Resistant Blower & Condenser FansRefrigerant ControlsChemical or Dust FiltrationDampersABS & A-60 compliantDisconnect SwitchHinged Doors
View Complete Details

Cabinet Coolers

CC series energy efficient closed-loop side and top-mount cabinet coolers provide cooling for Industrial Explosion Proof and Hazardous Duty Instrument Enclosures and Control Panels. Units range from 5, 000 24, 000 BTUH. Units equipped with internal condensation removal system. *Class I, Groups BCD, Division 1 & 2 conversions comply with NEC 500 & 505 Standards. (Group B, Division One Explosion Proof units require customer-furnished source of purge air.) *Class I, Groups IIAB, Zone 1 & 2 modifications conform to IEC European Standards. *Unit size will increase for Division 1 and Zone 1 units. Options: 50 HertzMany models available for 380 460 VAC316-Stainless Steel CabinetIndustrial Cabinet CoatingIntegrated controls for cabinet heaters
View Complete Details

Window Air Conditioner

CY Window, Heat Pump, and Thru-the-Wall Air Conditioners built specifically to provide electric heating and cooling for Industrial Hazardous Duty applications not requiring Pressurization or added Ventilation. Typical applications include Shelters, Containers, and Storage Facilities. Units range from 6, 000 to 36, 000 BTUH. All coils are protected with BLYGOLD PoluAl topcoat and 3509 primer. Class I, Groups BCD, Division 2 conversions comply with NEC 500 & 505 Standards. Class I, Groups IIAB, Zone 2 modifications conform to IEC European Standards. Click the link below to view Literature on this product. Options: 50 Hertz XP Electric Heat 316-Stainless Steel Frame and Cabinet Industrial Cabinet Coating Spark Resistant Blower & Condenser
View Complete Details

Explosion Proof Unit Heaters

Industry's Lowest Ignition Temperature Code Rating : T3C, 320F (160C)Dual Over temperature Protection: With both automatic and manual reset over temperature cutouts for additional safety.Nontoxic Propylene Glycol Heat Transfer FluidLow 70 PSIG Relief Valve Setting : This assures that in an emergency, the initial escaping vapor temperature remains below the 320F (160C) ignition temperature.Corrosive Resistant Options : Offered are three constructions suitable for most applications. Standard construction for use in dry non-corrosive areas includes : Welded steel heat exchanger; powder-coated cabinet; epoxy-coated motor. A 316 stainless steel construction suitable for Waste Water Treatment Plants includes : 316 stainless steel heat exchanger, headers and tubes with aluminum fins; stainless steel cabinet; corrosive resistance hardware; epoxy-coated motor. Third construction is suitable for use in Chemical Plants where chlorides are present and includes : corrosive resistance hardware; epoxy-coated motor.Explosion Proof Convectoin Heaters Designed to provide a heavy duty and corrosion resistant heat source. Features include: Wide Selection of Sizes: Four compact sizes to fit any space with ratings from 500 to 9500 watts.Sloped Top Cabinet: Prevents objects from being set on top of the convector, which can restrict airflow and cause overheating.Single and Three-Phase: Unique design provides single and balanced three-phase loads in a single element.Gas and Dust Atmospheres: Three listings cover the entire field, two for hazardous gases and vapors and one for dust particles.Wet Locations: All unit sizes available with iridite-coated elements and powder-coated frames for NEMA 3 wet locations.
View Complete Details

Explosion Proof Fans

Custom Controls Company XPF Series Explosion Proof Exhaust Fans draw air from hazardous locations to provide cooling or to exhaust hazardous concentrations of gasses. Common applications include paint storage lockers, battery rooms, laboratories, Safely Exhaust Air in Hazardous LocationsSpark Resistant Construction, units available to meet AMCA and ABS StandardsAvailable for wide range of Hazardous Area Classifications NEC Division One and Division Two, IEC Zone 1 and Zone 2Wide Range of available power supplies, both 50 and 60 Hz.Available Options include:o Rain Hoodo Filtrationo Matched inlet louvers and grilleso Gravity Damper (shutter)o Motor Operated isolation dampero Stainless Steel Housingo Temperature Controlso Redundant Configuration, with LeadLag Controlo Fan Proving Switcho Service Disconnect Switch Explosion Proof and Hazardous Location Supply Fans and Blowers are also available to force air into spaces. The XPF Series Supply Fans can be used to cool, ventilate, and purge spaces in Hazardous Locations. Supply and Exhaust Fans and Blowers are available in sizes from 200 CFM to 40, 000 CFM, for a wide range of static pressures. Please contact our Sales Dept. for additional information or for a quotation to meet your specific application.
View Complete Details

Condensing Units

CU Condensing Units range from 2 to 60 ton capacity, straight cooling or heat pump applications for Industrial Hazardous Duty applications. Pad or Roof mounted versions are available. Units require on-site Mechanical Contractor to run copper tubing and power to Condensing Unit. Typical applications include RIE Buildings, Motor Control Centers, Blast Buildings, Offshore Drilling Rigs, Containers, Man Camps, Storage Facilities, etc. Standard Features Include: Power Wiring in flexible conduitCoils and copper tubing coated with BLYGOLD PoluAl XT coating system.Intrinsically Safe High and Low Pressure SwitchesAvailable Options Include: 316 Grade stainless steel cabinetsMarine Grade cabinet coatingLow Ambient controlsRefrigerant Capacity Control Device for partial load operationUnits for 50 Hz. powerUnits for ABS requirementsHazardous Duty service disconnect switchClass I, Groups BCD, Division 2 units comply with NEC 500 & 505 and NFPA Standards. Class I, Groups IIAB, Zone 1 & 2 units conform to IEC European Standards.
View Complete Details

Roof Mount Air Conditioners

RVP Roof Mount Air Conditioners provide cooling and heating for Industrial Hazardous Duty applications. Typical applications include small Drillers Cabins, Guard Shacks, Well Logging Cabins and Portable Buildings. Units range from 13, 500 15, 000 BTUH. All coils and copper are protected with our BLYGOLD PoluAl XT coating system. Up to 3.0kW electric heat can be added with auto-changeover thermostat. Class I, Groups BCD, Division 2 units comply with NEC 500 & 505 Standards. Class I, Groups IIAB, Zone 2 modifications conform to IEC European Standards. Options: Hazardous Duty Electric HeatUnit Failure ContactsSpark Resistant Blower & CondenserHazardous Duty Disconnect Switch316 Grade Stainless Steel Housing50 Hz. PowerSplit area classifications Hazardous Duty Outside General Purpose Inside for Pressurized BuildingsDivision One (Groups C and D)
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • (Custom Controls Company)
  • Houston, TX 77081 map
  • Share us via

( ! ) Warning: Cannot modify header information - headers already sent by (output started at /htmlcachedir2/dynamic-html-pages/eitempfilen/usa/company/custom-controls-company/other-products.htm:44) in /home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php on line 59
Call Stack
#TimeMemoryFunctionLocation
10.0005458160{main}( ).../index.php:0
20.01672032968include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/country-vanity/country_index_page_common_script.php' ).../index.php:309
30.26042747016include_once( '/home/sgupta/exportersindia.com/htdocs/script-files/company-page/index.php' ).../country_index_page_common_script.php:282
40.26653687376header ( ).../index.php:59
ExportersIndia: 404 Error Found
404Oops! It seems this page is not available

We connect Buyers and Sellers

Tell us What you Need

Trending Categories

Find Suppliers by Region


View All Categories

Find Suppliers by Country

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice