ULLTRA High Performance Transformers

  • ULLTRA™ Ultra Low Loss Transformer
  • Optimized for any load level making ULLTRA the only transformer ideally suited for both light or hea Linear load losses are a full 30% lower than the already low levels defined by NEMA TP-1
  • Efficiencies meet NEMA Premium levels at the mandated 35% loading and even exceed these levels at th Harmonic losses are also reduced to ensure efficiencies meet NEMA TP-1 requirements even under ‘real world’ non-linear loading
ULLTRA High Performance transformers are designed to deliver more energy savings than any other transformer on the market. The result is a high performing transformer that offers the highest efficiency in the industry under either linear or non-linear loading and maintains these high efficiency levels at not only 35% loading, but over the entire load range. While other energy efficient transformers on the market may meet new, more demanding standards such as NEMA Premium and CSL3, these standards only restrict losses under linear loading and at 35% load levels. When it comes to higher load levels and non-linear loading, other transformers on the market cant offer the same high efficiencies under these conditions. ULLTRA High Performance transformers actually exceed NEMA Premium efficiency levels at their peak performance loading of 50%, thereby assuring the most energy savings under any loading.
View Complete Details

Drive Series Transformers

  • Brochures: Technical Data Sheets:
  • Drive Tamer™ Drive Tamer™
Phase shifting isolation transformers and autotransformers designed to produce cancellation of the characteristic harmonics of 3-phase rectifiers to produce effective 12-pulse 18-pulse, and 24 pulse schemes.Designed to replace standard drive isolation transformers, the Drive Tamer is built to not only withstand the harsh harmonic environment produced by Variable Frequency Drives (VFD), but to also induce cancellation of harmonics upstream and thereby reduce voltage distortion throughout the distribution system. By alternating 0 phase shifting models with 30 models, 5th and 7th harmonics are cancelled upstream. Where 3 loads are being serviced +20 , 0 , -20 models can reduce 5th, 7th, 11th and 13th harmonics, thereby dramatically reducing the voltage distortion these harmonics produce.
View Complete Details

Harmony Series Transformers

  • Harmonic No. Product
  • 3rd, 5th, 7th, 9th, 15th, 17th Harmony-2™*
HARMONY SERIES isolation transformers and autotransformers combine very low zero sequence impedance outputs with phase shifting for effective harmonic mitigation. They are designed to replace standard or k-rated transformers, especially when servicing single phase (120V L-N) non-linear loads, such as personal computers and other power electronic equipment.
View Complete Details