1 Products availableWe are leaders in the market for providing best range of Boiler Draft Boosters, Attack DP Gasification Boiler (35), Biomass Gasification Boiler (25), Attack DP Gasification Boiler (45) and Biomass Gasification Boiler (80)
Technical Specifications
Boiler output | kW | 35 (120kBtu) |
---|---|---|
Surface of exchanger | f2 | 30 |
Volume of fuel chamber | f3 | 367 |
Dimension of feeding opening | inches | 9.25 x 17.5 |
Prescribed chimney draught | Pa | 23 |
Max. operation overpressure of water | kPa | 250 |
Pressure loss of water (T 10K) | kPa | 4.4 |
Pressure loss of water (T 20K) | kPa | 1 |
Boiler weight | lb | 1014 |
Diameter of flue gas connection | inches | 5.9 |
Boiler height A | inches | 48.8 |
Boiler width B | inches | 27.6 |
Boiler depth C | inches | 52.75 |
Depth of chamber D | inches | 27.2 |
Protection of electrical parts | IP | 21 |
Electric output | W | 50 |
Boiler efficiency | % | 89 |
Boiler class | -- | 3 |
Flue gas temperature at nominal output | °F | 356 |
Substantive flue gas overflow at nominal output | kg/s | 0,021 |
Maximum noise level | dB | 65 |
Prescribed fuel | -- | Dry wood with heat value of 15-17 MJ/kg, water volume min. 12% -max. 20% diameter 80-150 mm |
Average fuel consumption | Kg/h | 9,1 |
Consumption per season | -- | 1 kW = 1 m3 |
Maximum length of wood logs | inches | 25.5 |
Burning time at nominal output | hod | 3 |
Volume of water in boiler | gallons | 29 |
Minimum volume of equalisation basin | l | 237.75 |
Connection voltage | V/Hz | 110/60 |
Technical Specifications
Rated Power Output | BTU | -- |
---|---|---|
European Standard EN 303-5 | -- | Yes |
Fuel Moisture Level | -- | Cord of Wood with a maximum of 30% moisture |
Power Range | BTU | 40-85K BTU |
Efficiency | % | 91.2 |
Possible Fuels | -- | Seasoned Wood, Briquettes, Corn Cobs with Kernels, 50% of Coal, Saw Dust, Wood Chips (50%), any kind of pellets |
Temperature Adjustment Range | A | 150-195 F |
Total Weight | Lb | 1190 |
Height with Controller Housing | A in | 59 |
Height of Hot Water Outlet | B in | 56 |
Height of Return Water Pipe | C in | 32 |
Height of Water Drain Valve | D in | 2.7 |
Height of Flue Pipe | E in | 46.5 |
Width with Clean-up Lever | F in | 25 |
Depth | H in | 39 |
Distance of Hot Water Outlet | I in | 9.5 |
Flue Pipe Size | J in | 6 |
Hot Water Outlet Pipe Size | G in | 2 |
Water Return Pipe Size | G in | 2 |
Drain Pipe Size | G | 3 |
Boiler Water Capacity | gal | 33 |
Flue Temperature | -- | -- |
-Max power output | A | 320 |
-Min power output | A | 195 |
Size of Loading Chamber | -- | -- |
depth | in | 19 |
height | in | 28 |
width | in | 18.5 |
Volume of Loading Chamber | gal | -- |
Noise Level | dB | 30 |
Power Consumption | W | 80W (1.4A) |
Voltage/Frequency | V/Hz | 120V/60Hz |
Technical Specifications
Boiler output | kW | 45 (154kBtu) |
---|---|---|
Surface of exchanger | f2 | 32.6 |
Volume of fuel chamber | f3 | 420 |
Dimension of feeding opening | inches | -- |
Prescribed chimney draught | Pa | 23 |
Max. operation overpressure of water | kPa | -- |
Pressure loss of water (T 10K) | kPa | 6.6 |
Pressure loss of water (T 20K) | kPa | 1.8 |
Boiler weight | lb | 1080 |
Diameter of flue gas connection | inches | -- |
Boiler height A | inches | -- |
Boiler width B | inches | -- |
Boiler depth C | inches | -- |
Depth of chamber D | inches | -- |
Protection of electrical parts | IP | -- |
Electric output | W | 60 |
Boiler efficiency | % | 90 |
Boiler class | -- | -- |
Flue gas temperature at nominal output | °F | 374 |
Substantive flue gas overflow at nominal output | kg/s | 0,027 |
Maximum noise level | dB | 65 |
Prescribed fuel | -- | Dry wood with heat value of 15-17 MJ/kg, water volume min. 12% -max. 20% diameter 80-150 mm |
Consumption per season | -- | -- |
Maximum length of wood logs | inches | 29.5 |
Burning time at nominal output | hod | 3 |
Volume of water in boiler | gallons | 33.8 |
Minimum volume of equalisation basin | l | 317 |
Connection voltage | V/Hz | -- |
Technical Specifications
Nominal output | 75 kW (256 KBTU) |
---|---|
Range of output setting (PROFI version) | 30-75 kW (102-256 KBTU) |
Prescribed chimney draught | 26 Pa |
Max water operation overpressure | 250 kPa (35 PSI) |
Pressure loss of water (T 10K) | 8.8 kPA (1.3 PSI ) |
Pressure loss of water (T 20K) | 1.6 kPa (0.23 PSI) |
Diameter of flue gas outlet | 200 mm (8) |
Loading chamber dimensions | -- |
Diameter of C.H. flow connection | 2 |
Diameter of C.H. return connection | 2 |
Protection level | 21 IP |
Maximum electric load | 4 A |
Boiler class | 3 |
Flue gas temperature by nominal output | 350 °F |
Flue gas flow by nominal output | 0.033 kg/s |
Average wood consumption | 18.7 kg/h |
Max wood log length | 1000 mm (40) |
Operation time by max.output | 2.5 h |
Volume of water in boiler | 164 l (43 Gal) |
Recommended accumulation tank min. volume | 500 Gal |
Range of water temperature setting | 65-90 oC ( 150 F to 195 F) |
Current carrying capacity of boiler regulato's contacts of (PROFI version) | 115V/4A |
Average wood consumption per season | 1kW=0.9m3 |
Efficiency | 86.2 % |
Fuel | Seasoned Wood (can be mixed with coal 40%) |
Electrical power connection | 115V/60Hz |
Weight | 650 kg (1422 lb) |
Heat-transfer surface | 3.6 m2 (39 sq/f) |
Max. noise level | 65 dB |
Feeding door size | 235445 mm ( 9.2x 17.5) |
Boiler width | 27.5 |
Boiler height | 57.5 |
Boiler depth | 66 |
Technical Specifications
Nominal output | 95 kW (325 KBTU) |
---|---|
Range of output setting (PROFI version) | 38-95 kW (140-325 KBTU) |
Prescribed chimney draught | 28 Pa |
Max water operation overpressure | |
Pressure loss of water (T 10K) | |
Pressure loss of water (T 20K) | |
Diameter of flue gas outlet | |
Loading chamber dimensions | L 41x W 21x H 31 |
Diameter of C.H. flow connection | |
Diameter of C.H. return connection | |
Protection level | |
Maximum electric load | |
Boiler class | |
Flue gas temperature by nominal output | |
Flue gas flow by nominal output | 0.035 kg/s |
Average wood consumption | 29.2 kg/h |
Max wood log length | |
Operation time by max.output | 3.5 h |
Volume of water in boiler | 250 l (65 Gal ) |
Recommended accumulation tank min. volume | |
Range of water temperature setting | |
Current carrying capacity of boiler regulato's contacts of (PROFI version) | |
Average wood consumption per season | |
Efficiency | 80.6 % |
Fuel | |
Electrical power connection | |
Weight | 800 kg (1900 lb) |
Heat-transfer surface | 5.6 m2 (60 sq/f) |
Max. noise level | |
Feeding door size | |
Boiler width | 30 |
Boiler height | 61 |
Boiler depth | 66 |
Futura Econo Coal Boiler is an automatic feeding system boiler. Futura Econo Coal Boiler is designed and developed for the purpose of combustion of granulated coal. The granulated coal (anthracite â hard coal), also known as Buckwheat or Rice coal, that is to be used in the Futura Econo Coal Boiler, should not be more than 3/4â³ in size. With minor adjustments, solid fuels like wood and wood pellets can also be burnt in the Futura Econo Coal Boiler. For the purpose of heating small buildings, Futura Econo Coal Boiler with an output of 85, 000 BTUs is suitable. When it comes to heating of buildings up to 12, 916 square feet, Futura Econo Coal Boiler an output of 171, 000 â 393, 000 BTUs is recommended. The automatic control system in the Futura Econo Coal Boiler facilitates convenient and reliable heating of indirect water heaters and domestic water. Features :
Technical Specifications
Model | Unit | 25 | 38 | 50 | 75 | 100 |
---|---|---|---|---|---|---|
Output | BTU | 85,000 | 119,000 | 171,000 | 256,000 | 342,000 |
Water Capacity | Gal | 27.30 | 33.80 | 46.80 | 65.00 | 81.90 |
Max. Operating Pressure | bar | 2 | ||||
Minimum Operating Temperature | °F | 145 | ||||
Max. Operating Temperature | °F | 194 | ||||
Recommended Min. Return Temperature | °F | 140 | ||||
Flue temperature | °F | >356 | ||||
Draft | WCI Pa |
0.08 20 |
0.08-0.10 20-25 |
0.10 25 |
0.10 25 |
0.10-0.12 25-30 |
Weight | Lbs. | 858 | 1078 | 1276 | 1562 | 1980 |
Brochure
FD Cast Iron Coal Boiler is meant for burning wooden briquettes, coal and wood. High quality cast iron sections are used to manufacture the FD Cast Iron Coal Boiler. This FD Cast Iron Coal Boiler has enlarged doors that facilitates convenient loading of huge fuel pieces. FD Cast Iron Coal Boiler is fitted with manually regulated secondary air combustion control and non-electric automatic draft controller. FD Cast Iron Coal Boiler is suitable for use in open or closed circulation heating systems along with open or pressure expansion vessels. Our offered FD Cast Iron Coal Boiler is appreciated for its smooth low temperature operation and long service life. Features :
Technical Specification
Segments | 8 |
---|---|
Nominal Heat Output | 144,000 Btu |
Minimum Heat Output | 43,000 Btu |
Combustion Chamber Volume | 16 gallons |
Water Volume | 9.5 gallons |
Maximum Overpressure | 25 PSI |
Weight | 772 lbs |
Depth | 34 inch |
Height | 40 inch |
Width | 19 inch |
Length of combustion chamber | 28 inch |
Width of combustion chamber | 12 inch |
Loading chamber dimensions (height x width x depth) | 9x 12x 28 inch |
Flue size | 6 inch |
Efficiency | 78-80% |
Tested pressure | 65 PSI |
C.H. water connection | 2 inch |
Drain Valve | 1/2 inch |
Cast Iron FD 42 Brochure