60L Benchtop Steam Autoclave

  • Steam Source Electrically generated in-chamber
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 13.8” (350mm) diameter x 24.4” (620mm) deep
  • Chamber Material Brushed grade 316L stainless steel
Many research, industrial, and teaching facilities in need of a benchtop lab sterilizer end up with a low-end tabletop medical sterilizer. Unfortunately, the plumbing and pressure vessels in these economical sterilizers arent up to research tasks. They often start to break down in the first 24 months, and are unrepairable after just five years. True research-grade benchtop autoclaves are built to last, with ASME-stamped 316L stainless steel pressure vessels. They offer all the flexibility, ease-of-use, and reliability that a small lab needs: Plug-n-play simplicity with fully featured programmable control systems optimized for media prep, liquid, and waste loads.
View Complete Details

40L Benchtop Steam Autoclave

  • Steam Source Electrically generated in-chamber
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 13.8” (350mm) diameter x 16.5” (420mm) deep
  • Chamber Material Brushed grade 316L stainless steel
All too often small labs shopping for benchtop sterilizers end up being sold low-end tabletop medical sterilizers. Unfortunately, the plumbing and pressure vessels in these economical sterilizers just arent up to research tasks. They start to break down in the first 24 months, and may be totally unrepairable after just five years. True research-grade benchtop autoclaves offer all the flexibility, ease-of-use, and reliability that a small lab needs: Plug-n-play simplicity with fully featured programmable control systemsQuality construction, with ASME-stamped 316L stainless steel pressure vesselsControl systems optimized to make running media prep, liquid, and waste loads fast and convenient
View Complete Details

150L Top Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber OR external generator
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 19.5” (496mm) diameter x 28.4” (720mm) deep
  • Chamber Material Brushed grade 316L stainless steel
  • Door Material Burnished grade 316L stainless steel
Top-loading steam autoclaves are the standard for lab work in Europe, and the #1 top-sellers for Priorclave UK worldwide. In fact, Priorclave recently fulfilled one of the largest autoclave orders in history for these sterilizers. These are among the most space- and energy-efficient models available today. Top-loaders are preferred for life-science research, as they easily accommodate the tallest flasks, fermentors, and bioreactorsat one-third the price of a comparable front-loading autoclave. Theyre also excellent for waste processing, especially in large batches. All Priorclave top-loading autoclaves are bench-height (regardless of capacity) and mounted on casters for easy installation and maintenance. Paired with the Loadlite integrated electrically operated hoist, any load can be pulled or placed almost effortlessly. Priorclave can even furnish custom baskets and tailor-made collars for hoisting fermentors and other specialized glassware.
View Complete Details

100L Top Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber OR external generator
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 19.5” (496mm) diameter x 19.5” (496mm) deep
  • Chamber Material Brushed grade 316L stainless steel
  • Door Material Burnished grade 316L stainless steel
Top-loading autoclaves like the 100L are the standard for lab work in Europe, and the #1 top-sellers for Priorclave UK worldwide because they are among the most space-efficient sterilizers available. They easily accommodate the tallest flasks, fermentors, and bioreactors, but cost one-third as much as a comparable front-loading autoclavemaking them popular with life-science research labs and academic institutions. Theyre also excellent for waste processingafter all, every trash can in your lab is a top loader. Priorclave top-loading autoclaves are bench-height (regardless of capacity) and mounted on casters, making them easy to install, and ideal for flexible spaces and regularly reconfigured facilities. Paired with the Loadlite integrated electrically operated hoist, any load can be pulled or placed effortlessly.
View Complete Details

60L Top Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 13.8” (350mm) diameter x 24.4” (620mm) deep
  • Chamber Material Brushed grade 316L stainless steel
Top-loading autoclaves are the standard for lab work throughout Europe, and the #1 top-sellers for Priorclave UK worldwide. Theyre among the most space-efficient models available. Top-loading sterilizers are preferred for life-science research because they easily accommodate the tallest flasks, fermentors, and bioreactorsand do so at one-third the price of comparable front-loading autoclaves. Theyre also excellent for waste processing: Loading is as easy as tossing a trash bag into your garbage can. All Priorclave top-loading autoclaves are bench-height (regardless of capacity) and mounted on casters, making them ideal for flexible spaces, regularly reconfigured facilities, or sharing among several neighboring labs.
View Complete Details

320L Front Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber OR external generator
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 24.8” (630mm) diameter x 40.2” (1020mm) deep
  • Chamber Material Brushed grade 316L stainless steel
  • Door Material Burnished grade 316L stainless steel
The advantages inherent in using a cylindrical-vessel sterilizer become especially apparent with large-volume front-loading autoclaves. By eliminating corners, the cylindrical vessel improves steam circulation, preventing cold pockets and assuring complete sterilization without excessive cycle times. If you arent processing flat trays of medical instruments on a daily basis, then you neither need nor want a rectangular-chamber autoclave. There are also impressive cost-savings associated with moving to a cylindrical-vessel sterilizer. A lower part count, more efficient steam generation, and lighter-gauge pressure vessel dont just reduce the purchase price, they drastically reduce maintenance and utility costs: On an annual basis, a cylindrical-vessel front-loading autoclave can be expected to use 75% less energy and 87% less water than a comparable energywater saving rectangular model. Every Priorclave front-loading sterilizer comes outfitted with an advanced Tactrol control system. These industry-favored control systems are optimized for research, offering exceptional cycle customization: One-touch operation, delayed cycle start, media warming, automatic cycle repeat, and more.
View Complete Details

200L Front Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber OR external generator
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 19.5” (496mm) diameter x 40.2” (1020mm) deep
  • Chamber Material Brushed grade 316L stainless steel
  • Door Material Burnished grade 316L stainless steel
Many labs rely on common rectangular-vessel autoclaves produced for the medical market. But if you arent processing flat trays of medical instruments, then you dont need a rectangular-chamber autoclaveand dont want one. This is especially the case with large-volume front-loading autoclaves: By eliminating corners, cylindrical-vessel sterilizers improve steam circulation, preventing cold pockets. This decreases overall heating and cooling times while increasing reliability, assuring that every load is properly processed. The cost-savings associated with moving to a cylindrical vessel sterilizer are also impressive. A lower part count, more efficient steam generation, and lighter-gauge pressure vessel dont just reduce the purchase price: On an annual basis, a cylindrical-vessel front-loading autoclave can be expected to use 75% less energy and 87% less water than a comparable energy andor water saving rectangular model, and spend far fewer days down for maintenance. Every Priorclave front-loading autoclave ships with an advanced Tactrol control system. These controls are optimized for research tasks, with unparalleled cycle customization: One-touch operation, delayed cycle start, media warming, automatic cycle repeat, and more.
View Complete Details

Dual 150L Front Loading Chambers Electrically Heated Autoclave

The EH150 Stackable laboratory autoclave is extensively used within many industries, including education, life sciences, pharmaceutical, agricultural, industrial, food and drink, dairy, and brewing. Operating Range: Up to 138C, 2.4 Bar (280F, 34.8psi)Working Dimensions: 496mm (19.5) diameter x 740mm (29.1) deep (upper and lower chambers)Chamber Material: Brushed grade 316L stainless steelDoor Material: Burnished grade 316L stainless steel Features Priorclave sterilizers are built in the UK to a modular design enabling easy upgrading during their working life as your requirements change. Every electrically heated Priorclave is fitted with a Thermostatic Air Purge Valve, Low Water Cut Out, and electrically operated Vent Valve. All pipe to pipe joints are brazed with compression joints to specific components (stainless pipework is available). Priorclave offers a 12 months parts and labor warranty and a 15 year pressure vessel warranty on this model. Safety All Priorclave autoclaves comply with current US, Canada, UK, and EU safety regulations, and are manufactured under an ISO 9001:2008 quality management system. All pressure vessels are manufactured in-house and tested to 1.5 times their maximum working pressure. They have full Insurance approval for pressure vessel design and construction and are CE Marked under the Pressure Equipment Directive PD5500:2000 Cat 3, Certificate Number SS42059010-2 Rev 1. They also conform to the general requirements of BS2646 and are CE Marked for BS EN61010-2-41, Low Voltage and Electromagnetic Compatibility. At Priorclave, the safety of your staff and students, comes first. Priorclave is the only manufacturer offering the sophisticated Tactrol 2 Control System on every model benchtop to double-ender. Program cycles are simple push-button andor keyswitch activated. Program modifications are keyswitch andor password protected, and interface directly with your PC. The Tactrol 2 controller has the unique ability to be as simple as it needs to be, or as sophisticated as your process demands. Everything is within your control, and no additional training is required when moving from one unit to another. The Quickseal 2 door, with Permission-based Door Release, is fitted with thermal and pressure locks preventing opening of the autoclave at load temperatures above 80C (176F) and pressures above 0.2 Bar (2.9 psi) (BS2646). The door is also fitted with a Redundant Safety Gate, allowing potential residual pressure to safely escape before the door can be fully opened (in accordance with the UK Health and Safety Executives note PM73). Fitted with a Pressure Safety Valve set to 2.5 Bar (36.3 psi) and a 150C (302F) thermal cut out (BS6759); selected external panels and surfaces are Thermally Insulated. All front loading models are fitted with non-tip shelves.
View Complete Details

100L Front Loading Steam Autoclave

  • Steam Source Electrically generated in-chamber OR external generator
  • Operating Range Up to 280°F, 34.8psi (138°C, 2.4 Bar)
  • Working Dimensions 19.5” (496mm) diameter x 21.1” (535mm) deep
  • Chamber Material Brushed grade 316L stainless steel
  • Door Material Burnished grade 316L stainless steel
Many of these facilities start out with mid-sized rectangular-vessel medical-grade sterilizers. These are great for quickly processing flat trays of medical instruments, but not great at anything else. This becomes more pronounced as the autoclave gets bigger: As rectangular chambers grow, operating costs and maintenance headaches can climb exponentially. Cylindrical-vessel front-loading sterilizers eliminate chamber corners, making for a more reliable device. Improved steam circulation prevents cold pockets, minimizing heating and cooling while ensuring properly processed loads. The cost-savings associated with moving to a cylindrical vessel sterilizer are also impressive. A lower part count, more efficient steam generation, and lighter-gauge pressure vessel dont just reduce the purchase price and nearly eliminate maintenance downtime: On an annual basis, a cylindrical-vessel front-loading autoclave can be expected to use 75% less energy and 87% less water than comparable energywater saving rectangular models. Every Priorclave autoclave is outfitted with an advanced Tactrol control system. These controls are optimized for research, with unparalleled cycle customization: One-touch operation, delayed cycle start, media warming, automatic cycle repeat, and more.