Our Products
Solar Pump
2 Products availableInverters, UPS & Converters
2 Products availableAuto Interior Accessories
2 Products availableCables And Wire Accessories
2 Products availableRouter, Cables & Networking Devices
1 Products availableIndustrial Pump
1 Products availableWe offer the best product range of Schneider Electric Conext ComBox, Outback Proharvest Trunk Cable, Fronius Modbus Card, Mersen Midget Fuse and Neurio Three Phase Expansion Kit.
Features:
True bankability
Higher return on investment
Designed for reliability
Flexible
Easy to service
Easy to install
Details
Programmable dry contact relay | Screw 3-terminal, 16-24 AWG, NC-Com-NO, Form: Class 2, 24 Vdc 4 A max |
---|---|
Graphical user interface | Internet Browser, Android tablet app |
Remote firmware upgrades | Yes (ComBox and connected Xanbus devices) |
Custom datalogger | Yes (requires Micro-SD card) |
Number of Xanbus devices | Up to 20 (depending on device type) |
Communication Interfaces
Xanbus | Connector: 2 x RJ45 Products Supported: Conext XW, SW, TX, GT-AUS, MPPT 60-150, MPPT 80-600, AGS, SCP |
---|---|
Ethernet | Connector: 1 x RJ45, 10 / 100 MBPS Server: FTP, Web, Modbus TCP/IP slave, SMTP, SNTP, Auto discovery: DPWS |
RS485 | Modbus (1 x Connector: Screw 5-terminal, 16-24AWG, 2-wire serial, 19200 bps) |
Data Interfaces
USB 2.0-Host | Connector: USB-A, Protocols: MSD (firmware upgrades and device locator) |
---|---|
USB 2.0-Device | Connector: USB-mini B, Protocols: MSD (data extraction) |
Power Supply Options
DC input | Certified / Listed / CE, using a 6.5 mm power plug, 9 - 24 Vdc (universal multi-pin AC adapter included) |
---|---|
Power consumption | <2 W typical / 10 W peak |
Xanbus | When connected to Conext XW, SW or MPPT 80 600, or more than one Conext TX |
RS485 connector | 24 Vdc input(safety extra low-voltage only) |
Memory
Internal | 96 MB flash |
---|---|
External | Micro-SD Card (2GB or more, class 2 or better recommended) |
Conext ComBox Android Tablet Application*
Software | Minimum Android version 4.0 (Ice Cream Sandwich), download via Google Play |
---|---|
Hardware | Minimum tablet screen size (7”, 1024 x 600, e.g. Acer Iconia Tab A100, Acer Iconia Tab A500, Google NexusTM 7, Asus Transformer TF700T, Samsung Galaxy TabTM 2 10.1) |
Features
Features :
Electrical Data
AC Voltage | 100 / 110 / 120 VAC |
---|---|
Rated Power | 600 Watts |
Surge Power | 800 Watts |
Waveform | True Sine Wave (THD <3%) |
Frequency | 50/60 Hz Selectable by DIP Switch |
AC Regulation | ± 3% |
Power Factor Allowed | COSØ -90o - COSØ +90o |
Standard Receptacles | NEMA 5-15R/GFCI |
No Load Current Draw | 0.23 Amps |
DC Voltage | 48 VDC |
Voltage Range | 42.0 - 60.0 VDC |
Efficiency | 0.92 |
Fuse | 10 Amps x 2 |
Battery Low Alarm | 44.0 VDC |
Battery Low Shutdown | 42.0 VDC |
Overload | Shut Off Output Voltage, Re-Power on to Recover |
Over Voltage | 61.2 VDC |
Over Temperature | Shut Off Output Voltage, Recovers Automatically After Temperature Goes Down |
Output Short | Shut Off Output Voltage, Re-Power on to Recover |
Battery Polarity Reverse | By Fuse Open |
Applications For The Fronius Modbus Card
Features/Benefits :
Applications :
Approvals :
Features:
Physical characteristics : Has plastic base 2.00 x 1.25 inches, with two mounting holes .205 "dia, .875 apart o.c. Overall height 1.7 inches. High current connections are made to two bolts (1/4"-28) which are 1.00" apart.
Sunction Capacity:
Choice of capacity
Construction:
Installation
Battery Choice : Pick the batteries that make the most sense for your area. You’re not limited by battery chemistry with Magnum Energy
Lightweight, Easy Install Design : Storm Kits offer an easy-to-install design, making it reasonable for a single solar contractor to install a system.
Maximum Energy Harvest : The kit includes an MPPT PT-100 Charge Controller, which harvest the maximum available energy from the PV array for optimal battery charging.
Indoor or Outdoor Installation : Storm Kits have options for installing a panel indoors, or outdoors in a NEMA 3R-rated weather resistant, protective enclosure.
Options : Choose from 4000 or 4400 watt AC output and 24 or 48 VDC battery input, creating the system that best suits your needs.
Proven Technology : Magnum Energy Storm Kits are built with proven technology, known to work in even the harshest environments, which provides peace-of-mind when the wind starts blowing.
Kit Includes
Inverter/Charger | MS4024PAE Inverter/Charger: 4000W, 24V parallel inverter, 105 amp PFC charger, 120/240V input/output |
---|---|
Charge Controller | PT-100 Charge Controller: 100 amp, MPPT charge controller with integrated AFCI and GFDI |
Panel | MMP250-30D Panel: Mini Magnum Panel with 250 amp DC breaker and 30 amp dual pole AC input breaker/bypass assembly |
Backplate | Backplate for one MMP Panel |
Remote Control | ME-ARC50 Remote: Advanced remote control with digital LCD display and 50’ cable |
Battery Monitor Kit | ME-BMK-NS: Battery monitoring kit |
Battery Breaker | BR-DC100-DIN: 100 amp DIN rail DC battery breaker |
PV Breaker | BR-PV50-DIN: 50 amp DIN rail PV breaker |
Battery Choice: Pick the batteries that make the most sense for your area. You’re not limited by battery chemistry with Magnum Energy
Lightweight, Easy Install Design: Storm Kits offer an easy-to-install design, making it reasonable for a single solar contractor to install a system.
Maximum Energy Harvest: The kit includes an MPPT PT-100 Charge Controller, which harvest the maximum available energy from the PV array for optimal battery charging.
Indoor or Outdoor Installation: Storm Kits have options for installing a panel indoors, or outdoors in a NEMA 3R-rated weather resistant, protective enclosure.
Options: Choose from 4000 or 4400 watt AC output and 24 or 48 VDC battery input, creating the system that best suits your needs.
Proven Technology : Magnum Energy Storm Kits are built with proven technology, known to work in even the harshest environments, which provides peace-of-mind when the wind starts blowing.
Kit Includes
Inverter/Charger | MS4024PAE Inverter/Charger: 4000W, 24V parallel inverter, 105 amp PFC charger, 120/240V input/output |
---|---|
Charge Controller | PT-100 Charge Controller: 100 amp, MPPT charge controller with integrated AFCI and GFDI |
Panel | MMP250-30D Panel: Mini Magnum Panel with 250 amp DC breaker and 30 amp dual pole AC input breaker/bypass assembly |
Enclosure | ME-ODE Outdoor Enclosure: NEMA 3R-rated outdoor enclosure to house MMP, MS-PAE, and charge controller |
Remote Control | ME-ARC50 Remote: Advanced remote control with digital LCD display and 50’ cable |
Battery Monitor Kit | ME-BMK-NS: Battery monitoring kit |
Battery Breaker | BR-DC100-DIN: 100 amp DIN rail DC battery breaker |
PV Breaker | BR-PV50-DIN: 50 amp DIN rail PV breaker |
Features
Compatible With:
Features:
Features
Product highlights
Product highlights
Features True bankability
Higher return on investment
Designed for reliability
Flexible
Easy to service
Easy to install
Features
Electrical Data
Grid & Generator Input (AC) / Loads Output On-Grid (AC) | |
---|---|
Continuous AC Output Power (25°C) | 7200 VA |
Input Voltage Range | 120/240V Split-Phase (60V-140V per Leg) |
Input Frequency Range | 50 Hz to 70 Hz |
Surge Amps (Overcurrent / Fault Limit) | L-L 70 AAC (1 mSec), 40 AAC (100 mSec) |
Maximum Continuous Current | 30 AAC |
Maximum Overcurrent Protection | 30 AAC |
Loads Output Off-Grid (AC) | |
Continuous AC Output Power (25°C) | 4400 VA |
Voltage Range | 120/240V (+/-5%) Split-Phase |
Frequency Range | 60 Hz (+/-0.1 Hz) |
Surge Amps (Overcurrent / Fault Limit) | L-L 70 AAC (1 mSec), 40 AAC (100 mSec) |
Surge Power | 8500 Real Watts (5 Seconds) |
AC Voltage Distortion at Rated Power | Less than 5% THD |
Renewables Input On-Grid and Off-Grid (AC) | |
Continuous AC Output Power (25°C) | 7200 VA |
Input Voltage Range | 120/240V Split-Phase (60V-140V per Leg) |
Input Frequency Range | 50 Hz to 70 Hz |
Surge Amps (Overcurrent / Fault Limit) | L-L 70 AAC (1 mSec), 40 AAC (100 mSec) |
Maximum Continuous Current | 30 AAC |
Maximum Overcurrent Protection | 30 AAC |
Battery Port | |
Input Voltage Range | 36V - 67.6V (48V Nominal) |
Maximum Continuous Current | 100 ADC (Analog-to-Digital Converter) |
Surge Amps (Overcurrent / Fault Limit) | 140 ADC (1 mSec) |
Maximum Torque for Battery Terminal | 30ft - lbs (40.6 Nm) |
Temperature Compensation (External) | 0°C to 50°C |
Battery Chemistry Compatibility | LiFePO4, AGM, FLA, an Gel |
Option 1 Chemistry AGM | Nominal Capacity 4.3 kWh |
Option 2 Chemistry LiFePO4 | Nominal Capacity 8.8 kWh |